Skip to content Skip to footer
0 items - P0.00 0

Industrial Metrology Services

Calibration Services

The process of establishing and rectifying the accuracy of a measuring or testing equipment.

BOBS Calibration Services
Calibration is critical in ensuring that measurement and test results from these instruments/equipment are accurate, trustworthy and reliable and as such assuring quality of the products.

Accreditation of Calibration Services :

BOBS temperature, dimension calibration services are accredited to ISO/IEC 17025 Standard as a third-party assurance that calibration laboratories are competent to carry out these services. Other services stated below comply with SADC Accreditation Services (SADCAS) TR09 requirements which entails measurement traceability compliance requirements. BOBS shall continue to accredit more services, keep on checking the website for the update….

Measurement Traceability and Internationally Recognised Measurements :

BOBS Standards used for calibration are all traceable to international systems of units (SI) therefore ensuring unbroken chain of comparison to SI. BOBS has its temperature measurements listed in the database of International Office of Weights and Measures (BIMP) confirming international recognition of temperature calibration measurements. Contact BOBS for more information…

BOBS is your calibration plug :

Do you require calibration services of your testing, production and measuring equipment? Look no further BOBS offers calibration services some of which are accredited and internationally recognised in the following fields:
Calibration of temperature measuring equipment. The equipment amongst others include:
– Liquid in glass thermometers -300C to 250 0C
– Digital thermometers -30 0C to 1000 0C
– Mechanical dial thermometers 0 0C to 60 0C
– Resistance thermometers -40 0C to 250 0C
– Thermocouple thermometers -30 0C to 1000 0C
– Ovens
– Incubators
– Fridges/freezers
Calibration of small volume measuring equipment particularly micropipettes in the range of 1 µl to 5 ml
Calibration of dimensional measuring equipment. The equipment include amongst others:
– Vernier callipers 0 to 500 mm;
– External micrometres 0 to 300 mm;
– Dial gauges 0 to 20 mm;
– Rulers 0 to 1000 mm and
– Measuring tapes.
Calibration of measuring equipment in the range of 0 to 2000kN. The equipment includes amongst others:
– Cube Press
– Tonnage Machines
– Load-Cells
– Hydraulic Jacks and
– CBRs
Calibration of time & frequency measuring equipment amongst others this include equipment such as:
– Centrifuges 0- to 30,000 rpm
– Timers
Calibration of pressure gauges in the range of 0 to 3500 kPa pneumatic and 0 to 70 Mpa hydraulic
Calibration of measuring equipment in the range of 0 to 1500Nm, both clockwise and anticlockwise direction. The equipment includes amongst others torque wrenches and torque transducers
Calibration of electrical measuring equipment in the ranges – Max Current: 2A; Max Voltage: 1100 V; Max Resistance: 10 MΩ.
This equipment include amongst others;
– Voltmeters
– Ammeters
– Clamp meters
– Electrical multimeters
– Insulation meters
– Other resistance measuring equipment
Examples of equipment/instruments include biosafety cabinets, modular labs and laminar flow cabinets

Safety Cabinets Certification

BOBS provides or arrange for validation of Biological Safety Cabinets, laminar flow cabinets and fume hood cabinets.
IMPARTIALITY AND CONFIDENTIALITY STATEMENT
The Botswana Bureau of Standards (BOBS) understands the importance of impartiality and confidentiality in carrying out its management system certification activities. BOBS management is committed to gaining and maintaining the reputation, credibility and ultimately, confidence of its stakeholders in rendering its certification services. Additionally, BOBS strives to continuously manage foreseen potential conflicts of duty and interest and ensures objectivity of its activities under the management system certification. To achieve the above, BOBS shall identify, analyse, record and manage potential conflict of duty and interest to ensure that certification services are not provided within relationships that have been identified to pose an unacceptable threat to impartiality. An Impartiality Committee shall periodically review activities of the certification function to verify commitment to credibility and fairness. The Committee shall further assist in the development of policies relating to impartiality of providing certification activities. BOBS is committed to maintaining in strict confidence all information accessed while rendering the certification services and shall ensure that such information is not divulged to third parties without the Client’s written consent unless if required by law.
Demand Quality

When things don't work as they should, it often means that standards are absent.

BOBS Head Office
Physical Address —
Plot No, 55745, Block 8, Mail Airport Road
Postal Address —
Private Bag B048,
Gaborone, Botswana
Francistown office
Physical Address —
Plot No, 32367, Donga,
Adjacent Metsef Wholesalers
Postal Address —
Private Bag F465,
Francistown, Botswana
BOBS Weighbridge
Physical Address —
Plot No: 20683, Ramakukane
Road, Block 3 Industrial,
Gaborone, Botswana
BOBS © Copyright 1992 – 2024. All Rights Reserved. Developed by Weblogic.
Go to Top