Skip to content Skip to footer
1 item - P245.00 1

BOS 563:2013

P475.00

Distribution of transformers – Specification

SKU: BOS 563:2013 Category: Product ID: 27777

Additional information

ICS Code

ICS Name

Edition

Pages

Published Date

Replaced by

Replaces

Sector

Standard Development Stage

Standard Status

Technical Committee

Type of Standards

Description

1.1 This standard specifies requirements for single-phase and three-phase distribution transformers, including installation requirements of the oil-immersed type that
i) are category-sized in accordance with IEC 60076-1 up to and including 3 150 kVA,
j) have rated maximum voltages (Um) that do not exceed 36 kV,
k) have uniformly insulated windings,
l) have a high-voltage and a low-voltage winding or, in the case of an auto-transformer, a series and a common winding and, in each case, if necessary, a stabilizing winding or an auxiliary winding, and
m) are suitable for off-circuit tap changing only. NOTE: Although distribution transformers are generally designed to receive power at a voltage that exceeds 3.3 kV and to deliver power to systems that have a nominal voltage of 230/400 V or 525 V, this standard covers transformers that have any combination of rated primary and secondary voltages. 1.2 This standard is not applicable to transformers that have more than two windings, other than those referred to in 1.1(d).
1.3 This standard applies to distribution transformers that are designed for use, at full continuous rating, under the conditions specified in IEC 60076-1 and also under the following conditions:
n) at an altitude that does not exceed 1 800 m; o) at a system voltage frequency of 50 Hz; and p) under the conditions to which the electrical installations being served could be exposed. Requirements that have to be specified by the NOTE: purchaser and those that have to be agreed upon by the manufacturer and the purchaser are listed in Annex A.

IMPARTIALITY AND CONFIDENTIALITY STATEMENT
The Botswana Bureau of Standards (BOBS) understands the importance of impartiality and confidentiality in carrying out its management system certification activities. BOBS management is committed to gaining and maintaining the reputation, credibility and ultimately, confidence of its stakeholders in rendering its certification services. Additionally, BOBS strives to continuously manage foreseen potential conflicts of duty and interest and ensures objectivity of its activities under the management system certification. To achieve the above, BOBS shall identify, analyse, record and manage potential conflict of duty and interest to ensure that certification services are not provided within relationships that have been identified to pose an unacceptable threat to impartiality. An Impartiality Committee shall periodically review activities of the certification function to verify commitment to credibility and fairness. The Committee shall further assist in the development of policies relating to impartiality of providing certification activities. BOBS is committed to maintaining in strict confidence all information accessed while rendering the certification services and shall ensure that such information is not divulged to third parties without the Client’s written consent unless if required by law.
Demand Quality

When things don't work as they should, it often means that standards are absent.

BOBS Head Office
Physical Address —
Plot No, 55745, Block 8, Mail Airport Road
Postal Address —
Private Bag B048,
Gaborone, Botswana
Francistown office
Physical Address —
Plot No, 32367, Donga,
Adjacent Metsef Wholesalers
Postal Address —
Private Bag F465,
Francistown, Botswana
BOBS Weighbridge
Physical Address —
Plot No: 20683, Ramakukane
Road, Block 3 Industrial,
Gaborone, Botswana
BOBS © Copyright 1992 – 2024. All Rights Reserved. Developed by Weblogic.
Go to Top